top of page
ZONE VALVE BOXES
AMICO Multiple Zone Indicator Panel Assembly
AMICO Single Sensor Indicator Panel Combo Unit
GENTEC Zone Valve Box
BALL VALVES
GENTEC Dual Port Ball Valves
Ball valves are composed of double seal, three piece in-line serviceable ball-type design, with forged bronze/brass body and chrome-plated brass ball. Only 1/4 turn of the handle is required to operate the valve from a fully open to fully closed position. The valves have a full port design and incorporate an adjustable packing and a blow-out proof stem.
Ball valves shall be designed for working pressure up to 600 psig WOG. Valve body shall have Teflon® material ball seat and Teflon® material stem seals. Seats/seals, lubricants and valve materials are compatible with USP oxygen, nitrous oxide, medical air, carbon dioxide, helium, nitrogen and mixtures thereof at continuous pressure up to 600 psig and vacuum service to 29” Hg. Ball valves shall be provided with type-K copper tube extensions, for making connections to the pipeline and shall include dual gauge/purge ports sealed with brass HEX plugs. Locking or non-locking handles are available (locks furnished and installed by others).
All ball valves shall be supplied clean and prepared for oxygen service in accordance with current CGA G-4.1 standards. All valves shall be 100% tested for leaks and manufactured to comply with the latest edition of NFPA99. Valves shall be plugged and sealed in a polyethylene bag to keep them clean prior to installation.
Ball valves shall be designed for working pressure up to 600 psig WOG. Valve body shall have Teflon® material ball seat and Teflon® material stem seals. Seats/seals, lubricants and valve materials are compatible with USP oxygen, nitrous oxide, medical air, carbon dioxide, helium, nitrogen and mixtures thereof at continuous pressure up to 600 psig and vacuum service to 29” Hg. Ball valves shall be provided with type-K copper tube extensions, for making connections to the pipeline and shall include dual gauge/purge ports sealed with brass HEX plugs. Locking or non-locking handles are available (locks furnished and installed by others).
All ball valves shall be supplied clean and prepared for oxygen service in accordance with current CGA G-4.1 standards. All valves shall be 100% tested for leaks and manufactured to comply with the latest edition of NFPA99. Valves shall be plugged and sealed in a polyethylene bag to keep them clean prior to installation.
GENTEC Dual Port Ball Valves
Ball valves are composed of double seal, three piece in-line serviceable ball-type design, with forged bronze/brass body and chrome-plated brass ball. Only 1/4 turn of the handle is required to operate the valve from a fully open to fully closed position. The valves have a full port design and incorporate an adjustable packing and a blow-out proof stem.
Ball valves shall be designed for working pressure up to 600 psig WOG. Valve body shall have Teflon® material ball seat and Teflon® material stem seals. Seats/seals, lubricants and valve materials are compatible with USP oxygen, nitrous oxide, medical air, carbon dioxide, helium, nitrogen and mixtures thereof at continuous pressure up to 600 psig and vacuum service to 29” Hg. Ball valves shall be provided with type-K copper tube extensions, for making connections to the pipeline and shall include dual gauge/purge ports sealed with brass HEX plugs. Locking or non-locking handles are available (locks furnished and installed by others).
All ball valves shall be supplied clean and prepared for oxygen service in accordance with current CGA G-4.1 standards. All valves shall be 100% tested for leaks and manufactured to comply with the latest edition of NFPA99. Valves shall be plugged and sealed in a polyethylene bag to keep them clean prior to installation.
Ball valves shall be designed for working pressure up to 600 psig WOG. Valve body shall have Teflon® material ball seat and Teflon® material stem seals. Seats/seals, lubricants and valve materials are compatible with USP oxygen, nitrous oxide, medical air, carbon dioxide, helium, nitrogen and mixtures thereof at continuous pressure up to 600 psig and vacuum service to 29” Hg. Ball valves shall be provided with type-K copper tube extensions, for making connections to the pipeline and shall include dual gauge/purge ports sealed with brass HEX plugs. Locking or non-locking handles are available (locks furnished and installed by others).
All ball valves shall be supplied clean and prepared for oxygen service in accordance with current CGA G-4.1 standards. All valves shall be 100% tested for leaks and manufactured to comply with the latest edition of NFPA99. Valves shall be plugged and sealed in a polyethylene bag to keep them clean prior to installation.
EMERGENCY OXYGEN CONNECTION BOXES
GENTEC Emergency Oxygen Connection Boxes
Emergency low pressure oxygen connection boxes are required by NFPA99 for most bulk oxygen installations. This emergency oxygen connection box is available in surface or recessed mount versions, with either a 3/4” or a 1-1/4” connection. Check valves, pressure relief valves, and pipe-away adapters are also available for purchase for a total piepline solution.
MEDICAL GAS OUTLETS
GENTEC Medical Gas Outlet Chemetron 90°
GENTEC Medical Gas Wall Outlet Quick Connect Puritan-Bennett® Compatible
GENTEC Australian Medical Gas Outlet
GENTEC British Gas Outlet
GENTEC British Standard gas outlet
AMICO Chemetron Wall Outlet
AMICO DISS Compact Wall Outlet
GENTEC DISS Gas Outlet
AMICO DISS Wall Outlet
AMICO Dual Connect Wall Outlet
GENTEC German Gas Outlets
AMICO Instrumental Air DISS (ISO) Wall Outlet
AMICO Instrumental Air DISS (NFPA) Wall Outlet
GENTEC Japanese Standard Gas Outlet
GENTEC DISS Ceiling Outlet
GENTEC Medical Gas Wall Outlet DISS® Compatible
GENTEC Medical Gas Wall Outlet Quick Connect Chemetron® Compatible 3823U-O outlet_2.jpg
GENTEC Medical Gas Wall Outlet Quick Connect Ohmeda® Compatible 3821U-O outlet_0.jpg
AMICO Ohmeda Compatible Compact Wall Outlet
AMICO Ohmeda Compatible Wall Outlet
MEDICAL GAS ALARMS
AMICO Alert 3 LCD Alarm
Features
•10" (25.4 cm) LCD screen
•Automatic gas detection
•Industry's smallest 8 gas alarm
•Clear display of alarm condition
•Self diagnostic and error message display
•10" (25.4 cm) LCD screen
•Automatic gas detection
•Industry's smallest 8 gas alarm
•Clear display of alarm condition
•Self diagnostic and error message display
AMICO Alert 4 LCD Ethernet Area Alarm
Feature
•The LCD alarm shall be capable of displaying an exact replica of the alarm on a computer screen via the facility's ethernet or internet. In addition, an exact image of the alarm can be displayed on a mobile device via wifi
•The LCD alarm will update its status every second
•Self diagnostic and error message display for ease of maintenance
•The LCD alarm shall be capable of displaying an exact replica of the alarm on a computer screen via the facility's ethernet or internet. In addition, an exact image of the alarm can be displayed on a mobile device via wifi
•The LCD alarm will update its status every second
•Self diagnostic and error message display for ease of maintenance
AMICO Combination Alarm Systems Compact/Master
Features
• Individual microprocessor for each display and sensor module
• Digital sensors can be mounted locally or remotely utilizing a #22 gauge stranded, shielding, twisted pair cable ONLY
• True digital LED read-out with RED alarm and GREEN normal trend indication of each service
• Illuminated LED display readable even in poor lighting conditions
• Self-diagnostic and error message display for ease of maintenance
• HIGH/LOW Alarm set-points are field adjustable for each individual gas service
• Alarm buzzer in excess of 90 decibels
• A green LED indicator for normal and a RED LED indicator for abnormal conditions
• Maintenance mode for ease of troubleshooting
• Self-diagnostic circuitry for added reliability
• Master modules can be upgraded in the field to interface to a building management system or slave master alarm
• Last alarm flashes, acknowledged alarm shows continuous RED signal
• Repeat alarm adjustable from 1, 12, 24 hours or off
• Dry contracts are used between master module and source equipment for remote monitoring of high and low alarms
• Sensors housed in a solid, tamper-proof enclosure to act as a barrier against any interference
• Gas specific sensor with DISS nut and nipple
• Individual microprocessor for each display and sensor module
• Digital sensors can be mounted locally or remotely utilizing a #22 gauge stranded, shielding, twisted pair cable ONLY
• True digital LED read-out with RED alarm and GREEN normal trend indication of each service
• Illuminated LED display readable even in poor lighting conditions
• Self-diagnostic and error message display for ease of maintenance
• HIGH/LOW Alarm set-points are field adjustable for each individual gas service
• Alarm buzzer in excess of 90 decibels
• A green LED indicator for normal and a RED LED indicator for abnormal conditions
• Maintenance mode for ease of troubleshooting
• Self-diagnostic circuitry for added reliability
• Master modules can be upgraded in the field to interface to a building management system or slave master alarm
• Last alarm flashes, acknowledged alarm shows continuous RED signal
• Repeat alarm adjustable from 1, 12, 24 hours or off
• Dry contracts are used between master module and source equipment for remote monitoring of high and low alarms
• Sensors housed in a solid, tamper-proof enclosure to act as a barrier against any interference
• Gas specific sensor with DISS nut and nipple
AMICO Compact Alarm Systems
Features
• Digital sensors can be mounted locally or remotely utilizing a #22 gauge stranded, shielding, twisted pair cable ONLY
• True digital LED read-out with RED alarm and GREEN normal trend indication of each service
• Illumination LED display readable even in poor lighting conditions
• Psi, kPa or BAR read-out (switch selected)
• HIGH/LOW Alarm set-points are field adjustable for each individual gas service
• Repeat alarm, adjustable 1 to 60 minutes or off
• Gas specific sensor with DISS nut and nipple. Display module with an error message for incorrect sensor to display connection
• Up to 12 gases in a standard configuration
• Alarm buzzer in excess of 90 decibels
• Individual microprocessor for each display and sensor module
• All modules mounted on a hinged frame for easy accessibility
• Dry contacts are used between master module and source equipment for remote monitoring of high and low alarms
• Sensors housed in a solid, tamper-proof enclousure to act as a barrier against any interference
• Digital sensors can be mounted locally or remotely utilizing a #22 gauge stranded, shielding, twisted pair cable ONLY
• True digital LED read-out with RED alarm and GREEN normal trend indication of each service
• Illumination LED display readable even in poor lighting conditions
• Psi, kPa or BAR read-out (switch selected)
• HIGH/LOW Alarm set-points are field adjustable for each individual gas service
• Repeat alarm, adjustable 1 to 60 minutes or off
• Gas specific sensor with DISS nut and nipple. Display module with an error message for incorrect sensor to display connection
• Up to 12 gases in a standard configuration
• Alarm buzzer in excess of 90 decibels
• Individual microprocessor for each display and sensor module
• All modules mounted on a hinged frame for easy accessibility
• Dry contacts are used between master module and source equipment for remote monitoring of high and low alarms
• Sensors housed in a solid, tamper-proof enclousure to act as a barrier against any interference
GENTEC Medical Gas Alarm Systems (Atlas) GM100M Combination alarm
Features
• The Atlas provides master, area, and combination alarm signals as required by the latest edition of NFPA99.
• The alarm is ETL listed to UL 1069 and CSA C22.2 No. 205 Signal Equipment
• On-site customization without the use of a laptop, tablet, or mobile device.
• 10” (25.4cm) Touch Screen Display with Password protected interface.
• Full networking capabilities including Modbus RTU/TCP, UDP protocols.
• A Trend Log to view the pressure trends and forecast if maintenance or additional support is required.
• An Event Log allows for a view history of time-stamped alarm events.
• Built-in webpage for viewing alarm conditions.
• Can be connected via VNC apps for smartphone and tablets.
• The Atlas provides master, area, and combination alarm signals as required by the latest edition of NFPA99.
• The alarm is ETL listed to UL 1069 and CSA C22.2 No. 205 Signal Equipment
• On-site customization without the use of a laptop, tablet, or mobile device.
• 10” (25.4cm) Touch Screen Display with Password protected interface.
• Full networking capabilities including Modbus RTU/TCP, UDP protocols.
• A Trend Log to view the pressure trends and forecast if maintenance or additional support is required.
• An Event Log allows for a view history of time-stamped alarm events.
• Built-in webpage for viewing alarm conditions.
• Can be connected via VNC apps for smartphone and tablets.
Medical Gas Alarm Systems (Atlas) GM100M-Master alarm
Features
• The Atlas provides master, area, and combination alarm signals as required by the latest edition of NFPA99.
• The alarm is ETL listed to UL 1069 and CSA C22.2 No. 205 Signal Equipment
• On-site customization without the use of a laptop, tablet, or mobile device.
• 10” (25.4cm) Touch Screen Display with Password protected interface.
• Full networking capabilities including Modbus RTU/TCP, UDP protocols.
• A Trend Log to view the pressure trends and forecast if maintenance or additional support is required.
• An Event Log allows for a view history of time-stamped alarm events.
• Built-in webpage for viewing alarm conditions.
• Can be connected via VNC apps for smartphone and tablets.
• The Atlas provides master, area, and combination alarm signals as required by the latest edition of NFPA99.
• The alarm is ETL listed to UL 1069 and CSA C22.2 No. 205 Signal Equipment
• On-site customization without the use of a laptop, tablet, or mobile device.
• 10” (25.4cm) Touch Screen Display with Password protected interface.
• Full networking capabilities including Modbus RTU/TCP, UDP protocols.
• A Trend Log to view the pressure trends and forecast if maintenance or additional support is required.
• An Event Log allows for a view history of time-stamped alarm events.
• Built-in webpage for viewing alarm conditions.
• Can be connected via VNC apps for smartphone and tablets.
Medical Gas Alarm Systems (Atlas) GM100M Area alarm
Features
• The Atlas provides master, area, and combination alarm signals as required by the latest edition of NFPA99.
• The alarm is ETL listed to UL 1069 and CSA C22.2 No. 205 Signal Equipment
• On-site customization without the use of a laptop, tablet, or mobile device.
• 10” (25.4cm) Touch Screen Display with Password protected interface.
• Full networking capabilities including Modbus RTU/TCP, UDP protocols.
• A Trend Log to view the pressure trends and forecast if maintenance or additional support is required.
• An Event Log allows for a view history of time-stamped alarm events.
• Built-in webpage for viewing alarm conditions.
• Can be connected via VNC apps for smartphone and tablets.
• The Atlas provides master, area, and combination alarm signals as required by the latest edition of NFPA99.
• The alarm is ETL listed to UL 1069 and CSA C22.2 No. 205 Signal Equipment
• On-site customization without the use of a laptop, tablet, or mobile device.
• 10” (25.4cm) Touch Screen Display with Password protected interface.
• Full networking capabilities including Modbus RTU/TCP, UDP protocols.
• A Trend Log to view the pressure trends and forecast if maintenance or additional support is required.
• An Event Log allows for a view history of time-stamped alarm events.
• Built-in webpage for viewing alarm conditions.
• Can be connected via VNC apps for smartphone and tablets.
GAS CONTROL PANEL
AMICO Gas Control Panel
Features
• Inlet and outlet pressure display gauge in psi/ kPa
• Manual shut-off valve
• Outlet supply pipe for remote mounted outlets
• 3/8" (9.5 mm) internal tubing for high flow
• High flow capacity regulator
• Wall mount with adjustable brackets for different wall thicknesses
• Aluminum front simplifies cleaning
• Maximum supply pressure: 250 psi (1,724 kPa)
• DISS maximum delivery pressure:
- Carbon Dioxide = 80 psi (551 kPa)
- Nitrogen = 200 psi (1,379 kPa)
- Instrument Air = 200 psi (1,379 kPa)
- HP (High Pressure) Safety Swing Coupling = 250 psi (1,723 kPa)
• Inlet and outlet pressure display gauge in psi/ kPa
• Manual shut-off valve
• Outlet supply pipe for remote mounted outlets
• 3/8" (9.5 mm) internal tubing for high flow
• High flow capacity regulator
• Wall mount with adjustable brackets for different wall thicknesses
• Aluminum front simplifies cleaning
• Maximum supply pressure: 250 psi (1,724 kPa)
• DISS maximum delivery pressure:
- Carbon Dioxide = 80 psi (551 kPa)
- Nitrogen = 200 psi (1,379 kPa)
- Instrument Air = 200 psi (1,379 kPa)
- HP (High Pressure) Safety Swing Coupling = 250 psi (1,723 kPa)
GENTEC Gas Control Panel
Gentec Gas Control Panels are designed to regulate medical gas pressure with either Nitrogen or Instrument Air DISS fitting in the panel. The one body design makes installation easy and regulation convenient.
CHECK VALVES
Medical Check Valves with Extensions
Features
• Available in sizes 3/4" to 4"
• 3 piece design for ease of maintenance
• Type K Copper Extensions
• Dual gauge/purge ports
• High flow, minimal pressure drop
• Cleaned for oxygen service
• 100% Hydrostatically tested
• NFPA-Compliant
• Available in sizes 3/4" to 4"
• 3 piece design for ease of maintenance
• Type K Copper Extensions
• Dual gauge/purge ports
• High flow, minimal pressure drop
• Cleaned for oxygen service
• 100% Hydrostatically tested
• NFPA-Compliant
Medical Check Valves with Extensions
Features
• Available in sizes 3/4" to 4"
• 3 piece design for ease of maintenance
• Type K Copper Extensions
• Dual gauge/purge ports
• High flow, minimal pressure drop
• Cleaned for oxygen service
• 100% Hydrostatically tested
• NFPA-Compliant
• Available in sizes 3/4" to 4"
• 3 piece design for ease of maintenance
• Type K Copper Extensions
• Dual gauge/purge ports
• High flow, minimal pressure drop
• Cleaned for oxygen service
• 100% Hydrostatically tested
• NFPA-Compliant
bottom of page